Current Location:Home > Products & Solutions > Vehicle Power Supply > 6kW Vehicle-Mounted DC/DC Power Supply
6kW Vehicle-Mounted DC/DC Power Supply
6kW Vehicle-Mounted DC/DC Power Supply

This product operates within an input voltage range of 400–950 Vdc, delivering a rated output of 27.5 Vdc/6000 W (peak power 6600 W). It features integrated liquid cooling for thermal management, along with input overvoltage/undervoltage alarm and protection, output overcurrent alarm and protection, output overvoltage protection, output short-circuit protection, overtemperature protection, CAN communication, and scheduled wake-up functionality. Suitable for various new energy vehicles including

Technical Specifications

ProjectMinimumTypicalMaximumUnitConditions
Environmental Conditions
Operating Temperature-40-85Derating begins when the base plate temperature exceeds 70°C, with a reduction of 3A per degree.
Storage temperature-40-105
Relative humidity5-95%No condensation during normal operation
Elevation0-3000m
Heat dissipation methodLiquid cooling
Input Characteristics
Rated Input Voltage560VdcThe input end features reverse polarity protection.
Input Voltage Range400-950Vdc
Maximum Input Current--18ALow-voltage full load
Static leakage current--3mAWhen the auxiliary power supply is not energized and the main power supply does not start, measure the input current at the rated input condition of the main power supply.
Output Characteristics
Rated Output Voltage27.5VdcRated input, output half-load
Output voltage setting27.5±0.3Vdc
Output Current Range0-220A400-450V only for CV load operation
Maximum Output Current220AMaximum continuous operating current at 450V and above
Output rated power6000W
Peak output power6600WPeak power: 6600W Operating time: 6 minutes
Overall efficiency93--%Under rated voltage input and full-load output conditions, Pout/Pin ≥ 93%.
Temperature coefficient--±0.02%/℃
Output ripple and noise--600mVmVp-pThe oscilloscope bandwidth should be 20MHz, with probes connected in parallel to a 10uF + 104 capacitor; testing should be conducted with the output carrying a load of 15% or more.
Boot-up time--3s
Output rise time--200mS0-20V
-2.5S20-27.5V
Voltage Regulation Accuracy--±1%
Scheduled Wake-Up Function----Supports freely adjustable timer wake-up function from 5 minutes to 24 hours.
Static leakage current--3mALeakage current when the output terminals are connected in parallel to a 24Vdc battery without being connected to high-voltage power supply or 24Vdc control power.
Control MethodCAN Control/EN Control/Reserve CAN wake-up function


Partner with VAPEL, Power the Sustainable Energy Tomorrow.
Call us or leave a message online, and we will provide attentive service and promptly assign a professional to assist you.
Privacy Policy
×

Platform Information Submission-Privacy Policy

· Privacy Policy