Current Location:Home > Products & Solutions > Vehicle Power Supply > 6kW Vehicle-Mounted DC/DC Power Supply
6kW Vehicle-Mounted DC/DC Power Supply
6kW Vehicle-Mounted DC/DC Power Supply

This product operates within an input voltage range of 550–950 Vdc, delivering a rated output of 27.8 Vdc/6000 W (peak power 6600 W). It features integrated liquid cooling for thermal management, along with input overvoltage/undervoltage alarm and protection, output overcurrent alarm and protection, output overvoltage protection, output short-circuit protection, overtemperature protection, CAN communication, and scheduled wake-up functionality. Suitable for various new energy vehicles including

Technical Specifications

ProjectMinimumTypicalMaximumUnitConditions
Environmental Conditions
Operating Temperature-40-60Derating begins when the base plate temperature exceeds 70°C, with a reduction of 5A per degree.
Shutdown at 90°C, resume at 75°C. (Combined with MOS temperature)
Storage temperature-40-85The power supply does not turn on.
Relative humidity5-95%No condensation during normal operation
Elevation0-3000m
Heat dissipation methodAir-cooled
Dustproof and waterproofIP68
Input Characteristics
Rated Input Voltage560VdcInput side features reverse polarity protection
Input Voltage Range550-950Vdc
Maximum Input Current--18ALow-voltage full load
Static leakage current--3mAWhen the auxiliary power supply is not energized and the main power supply does not start, measure the input current at the rated input condition of the main power supply.
Output Characteristics
Rated Output Voltage27.8VdcRated input, output half-load
Output voltage setting27.8±0.3Vdc
Output Current Range0-220A
Maximum Output Current220ALong-term operating current
Output rated power6000W
Peak Output Power6600WPeak power: 6600W Operating time: 6 minutes
Overall efficiency95--%Under rated voltage input and full-load output conditions, Pout/Pin ≥ 95%.
Temperature coefficient--±0.02%/℃
Output ripple and noise--500mVmVp-pThe oscilloscope bandwidth should be 20 MHz, with probes connected in parallel to a 10uF + 104 capacitor; testing should be conducted with the output carrying a load of 15% or more.
Boot-up time--3sInput voltage to output voltage: 10%
Output rise time--300mS2.75-18V
-2.5S18-25V
Voltage Regulation Accuracy--±1%